Page 18
Reset circuit breaker.
Reset GFCI.
Let cool for 1 hour. Motor overload will reset
automatically. If problem persists, contact your
Caldera dealer.
Disconnect spa and contact your Caldera dealer.
Add water to normal level (1 inch above highest
jet).
Open all knife valves.
Open or clean air valve.
Add water to normal level (1 inch above highest
jet).
Clean filter cartridge.
Open all knife valves.
Remove jet face eyeball and clean orifice.
• Clean suction cover or skimmer basket.
Set control panel to a higher temperature.
Align spa cover.
Switch to standard mode and/or lengthen filter
cycles.
Clean filter cartridge.
• Circuit breaker tripped or OFF.
• Motor overload condition.
• Control switch failure.
• Low water level.
• Knife valves closed.
• Air control valve closed or blocked.
• Low water level.
• Dirty filter cartridge.
• Knife valves partially or fully closed.
• Jet blocked.
• Clogged suction or skimmer basket.
• Temperature set too low.
• Spa cover improperly positioned.
• Filter cycles too short in Economy mode.
• Dirty filter cartridge.
If your spa doesn’t seem to be working the way you believe it should, please review the “START-UP” and “OPERATION”
instructions in this manual. If this doesn’t help you correct the problem, follow the appropriate instructions below. If
the problem still is not resolved, call your Caldera dealer.
Nothing works, Blank LCD
screen
Noisy pump or Motor
Pump motor will not function
Pump motor runs, but low or
no water/jet pressure
Spa not heating properly
• Sand or grit inside valve. • Clean and lubricate valve per instructions on
page 12.
Power Diverters are difficult
to turn
SYMPTOM PROBABLE CAUSE SOLUTIONS
Upon filling or refilling the spa, if a pump is operating and water is not flowing from any of its jets,
the pump may not be properly primed. To correct, refer to the “Equipment Compartment” illustra-
tion on page 13 and perform the following procedures:
Turn off power to the spa at the breaker and remove the equipment compartment door.
Loosen the union on the top of the pump to allow the air to escape. When water is present,
hand-tighten the union.
Turn power back on, activate the pump and check to make sure union is tight enough to keep it
from leaking.
Priming the pump